FarSite Network Connection Cables

The table below provides a FarSync adapter compatibility matrix for cables supplied by FarSite, discontinued products are also shown in the matrix.

For the cable wiring details and pin outs click on the links where shown.

FarSync Network Connection Cables - Compatibility Matrix

FarSync Network Connection Cables - Compatibility Matrix
FarSync PCI and Universal PCI cards FarSync PCI express (PCIe) cardsFarSync Flex USB Adapters
Cable name (Pinout pdf)Product code equivalentDescription
Cables are 1.5 metres unless stated otherwise
Cable image T1U*T2U*T4U*T4E* & T4E+*T2Ue*T4UeT2Ee*, K2Ee & BERT PCIeT4EeFlex, BERT USB
KCR1-V2FS6011FarSite HD26 to 1 combined EIA-530 (RS422) & RS232 DTE DB25M interface with Terminal Timing Click HereNoNoNoNoNoNoNoNoYes
KC449FS6019FarSite HD26 to RS449 (RS422) DTE DB37M interface Click HereNoNoNoNoNoNoNoNoYes
MCX4FS6041FarSite HD62 to 4 X.21 DTE DB15M interfaces Click HereNoNoYesNoNoYesNoNoNo
MCV4FS6042FarSite HD62 to 4 V.35 DTE M34M interfaces Click HereNoNoYesNoNoYesNoNoNo
MCR4FS6043FarSite HD62 to 4 RS232 DTE DB25M interfaces Click HereNoNoYesNoNoYesNoNoNo
TCX1FS60521 port EIA-530 to X.21 DTE DB15M transition connector Click HereNoNoNoYes with HCR4 NoNoYes with FCR2Yes with HCR4 No
TCV1FS6053 1 port EIA-530 to V.35 DTE M34M transition connector Click HereNoNoNoYes with HCR4 NoNoYes with FCR2Yes with HCR4 No
TC449FS60541 port EIA-530 to RS449 DTE DB37M transition connector Click HereNoNoNoYes with HCR4 NoNoYes with FCR2Yes with HCR4 No
UCR1FS6061FarSite HD26 to 1 RS232 DTE DB25M interface Click HereYesYesYes with MTU4NoYesYes with MTU4NoNoNo
UCX1FS6062FarSite HD26 to 1 X.21 DTE DB15M interface Click HereYesYesYes with MTU4NoYesYes with MTU4NoNoYes
UCV1FS6063FarSite HD26 to 1 V.35 DTE M34M interface Click HereYesYesYes with MTU4NoYesYes with MTU4NoNoYes
U530FS6064FarSite HD26 to 1 RS530 DTE DB25M interface Click HereYesYesYes with MTU4NoYesYes with MTU4NoNoNo
UXD1FS6069FarSite HD26 to connect direct to a Nortel DMS100 (NTFX35AA) Click HereYesYesYes with MTU4NoYesYes with MTU4NoNoYes
KCR1-DCEFS6070FarSite HD26 to 1 combined EIA-530 (RS422) & RS232 DCE DB25F interface Click HereNoNoNoNoNoNoNoNoYes
MTU2FS6072Transition cable - FarSite DB37 to 2 standard FarSite HD26 interfaces, 0.5 metres. Allows UCR1, UCX1, U530 and UCV1 cables to be used with FarSync T2P and X.PORT cards Click HereNoNoNoNoNoNoNoNoNo
FCR1FS60731 port EIA-530 & RS232 DTE cable, 1.5 metres for K2Ee or T2Ee only Click HereNoNoNoNoNoNoYesNoNo
MTU4FS6074Transition cable - FarSite HD62 to 4 standard FarSite HD26 interfaces, 0.5 metres. Allows UCR1, UCX1, U530 and UCV1 cables to be used with the FarSync T4U, T4Ue and T4P cards Click HereNoNoYesNoNoYesNoNoNo
HCR4FS60764 port EIA-530 & RS232 DTE DB25M cable, 2.0 metres for T4E and T4E+ only Click HereNoNoNoYesNoNoNoYesNo
FCR2FS60772 port EIA-530 & RS232 DTE DB25M cable, 1.5 metres for K2Ee or T2Ee only Click HereNoNoNoNoNoNoYesNoNo
FCX2FS60782 port X.21 DTE DB15M cable, 2.0 metres for K2Ee or T2Ee only Click HereNoNoNoNoNoNoYesNoNo
FCV2FS60792 port V.35 DTE M34M cable, 2.0 metres for K2Ee or T2Ee only Click HereNoNoNoNoNoNoYesNoNo
FC449FS60802 port RS449 DTE DB37M cable, 3.0 metres for K2Ee or T2Ee only Click HereNoNoNoNoNoNoYesNoNo
UX35CFS6095FarSite HD26 to 1 V.35 DCE M34F interface Click HereYesYesYes with MTU4NoYesYes with MTU4NoNoNo
MCX2XP8921FarSite DB37 to 1 RS232 and 1 X.21 DTE DB15M interface Click HereNoNoNoNoNoNoNoNoNo

FarSync Network Connection Cables - further cable types

FarSync Network Connection Cables - further cable types
Cable name (Pinout pdf)DescriptionImage Products using the cable
MCE1E1 cable with RJ48 connectorsClick HereFarSync TE1, FarSync TE1R, FarSync TE1e
JCD1SHDSL 4 wire cable with RJ11 connectors Click HereFarSync DSL-S1

FarLinX Gateway and FarLinX Bridge Connection Cables

FarLinX Gateway and FarLinX Bridge Connection Cables
Cable name (Pinout pdf)Product code
equivalent
Description
Cables are 1.5 metres unless stated otherwise
ImageProducts using the cable
GCR1-DTEFS6006RS232/RS530 DTE (V.24, X.21bis/ EIA530) cable with DB25M connectorClick HereFarLinX Connect Mini, FarLinX Mini Gateway
GCX1-DTEFS6007X.21 DTE (V.11) cable with DB15M connectorClick HereFarLinX Connect Mini, FarLinX Mini Gateway
GCV1-DTEFS6008V.35 DTE cable with standard M34M connectorClick HereFarLinX Connect Mini, FarLinX Mini Gateway
GCR1-DCEFS6001RS232/RS530 DCE (V.24, X.21bis/ EIA530) cable with DB25F connectorClick HereFarLinX Connect Mini, FarLinX Mini Gateway
GCX1-DCEFS6002X.21 DCE (V.11) cable with DB15F connectorClick HereFarLinX Connect Mini, FarLinX Mini Gateway
GCV1-DCEFS6003V.35 DCE cable with standard M34F connector (V.35F)Click HereFarLinX Connect Mini, FarLinX Mini Gateway

Cable Diagrams - FarSync Line Monitoring Cables

Cable Diagrams - FarSync Line Monitoring Cables
Cable name (Pinout pdf)Description

Cables are 2 metres unless stated otherwise
ImageProducts using the cable
KCR-MONLine Monitor cable for RS232 (V.24) and RS530 (RS422) with DB25M to DB25F pass-throughClick HereFarSync Flex & BERT USB
KCX-MONLine Monitor cable for X.21 (V.11) with DB15M to DB15F pass-throughClick HereFarSync Flex & BERT USB

FarSync Test Loopback Connectors - Compatibility Matrix

These loopback plugs are suitable for use with the test programs for the FarSync range of cards and devices. For the cable wiring details and pin outs click on the links where shown.

Cable Diagrams - Card Test Loopback Connectors - Adapter Compatibility Matrix
Cable nameProduct code equivalentDescriptionImageT1U*T2U*T4U*T2Ue*T4UeT4E*, T4E+*, T4EeT2Ee, K2Ee, BERT PCIeFlex, BERT- USB
Test-T2UFS6024FarSite HD26 loopback test plug suitable for testing the T1U, T2U and T2Ue in RS232 (V.24) and X.21 (V.11) configurations.Click HereYesYesNoYesNoNoNoYes
Test-T4P-RS232CFS6025FarSite HD62 loopback test plug suitable for testing T4U, T4Ue and T4P 4 port communications cards in a RS232 (V.24) configuration.Click HereNoNoYesNoYesNoNoNo
Test-T4P-X.21noneFarSite HD62 loopback test plug suitable for testing T4U, T4Ue and T4P 4 port communications cards in a X.21 (V.11) configuration.Click HereNoNoYesNoYesNoNoNo
Test-T4EFS6026FarSite 100-pin loopback test plug suitable for testing T4E, T4E+ and T4Ee 4 port communications cards in RS232 (V.24), RS530 (RS422), V.35 and X.21 (V.11) configurations.Click HereNoNoNoNoNoYesNoNo
Test-F2FS6027FarSite 44-pin loopback test plug suitable for testing T2Ee 2 port communications card in RS232 (V.24), RS530 (RS422), V.35 and X.21 (V.11) configurations.Click HereNoNoNoNoNoNoYesNo

Null-Modem Cables

Null-Modem cables are also often known as Crossover Cables can be used in place of a pair of synchronous modems or a modem eliminator provided a device at one end of the link can generate clocks. Another way to describing them is that they convert the interface presentation from DTE to DCE. They are compatible with all our current products which feature RS232, RS530 or X.21 network interfaces.

Null-Modem Cables - Compatibility Matrix
FarSync
Cable nameProduct code
equivalent
Description ImageFlex & BERT USBT1U*T2U*T2Ue*K2Ee/T2Ee*T4U*T4UeT4E/T4E+*T4Ee
Null-MXFS6090X.21 (V.11) null modem cable DB15F connectors. 0.5 metresClick HereYesYesYesYesYesYesYesYesYes
Null-MR3FS6092RS232 (V.24) null modem cable DB25F connectors. 0.5 metresClick HereYesYesYesYesYesYesYesYesYes
Null-MR4FS6097RS530 (RS422) null modem cable DB25F connectors, 0.5 metresClick HereYesYesYesYesYesYesYesYesYes

Network Interface Conversion Cables

The cables in this table indicate the wiring changes required to support other network interfaces different to those supplied as standard by FarSite. Click on the links for the cable wiring details and pin outs.

Network Interface Conversion Cable - Compatibility Matrix
Cable nameProduct code
equivalent
DescriptionT1U*T2U*T2Ue*K2Ee/T2Ee*T4U*T4UeT4Ee
X21-449-INTFS6093X.21 to RS449 Conversion. Can be attached to the end of a X.21 (V.11)
connector terminated cable from the card to provide an RS449 interface.
There are a two variations of the cable (X21-449-EXT and X21-449-INT)
depending on which end of the link generates the clocks.
YesYesYesYesYesYesYes
X21-449-EXTFS6094
X21-530noneX.21 to EIA-530 Conversion. Can be attached to the end
of a X.21 (V.11) connector terminated cable from the card to provide an
EIA-530 interface.
YesYesYesYesYesYesYes

* legacy card subject to special order conditions, not recommended for new projects
** card no longer available